A-116 – Yaskawa MP2300S Basic Module User Manual
Page 438

Appendix G MSG-SND/MSG-RCV Functions (Ethernet)
G.2 Message Receive Function (MSG-RCV)
A-116
Example: “Writes to multiple holding registers” with offset is received:
When “writes to multiple holding registers” with offset is received in MEMOBUS protocol, various setting values and the
relationship with the data of remote equipment are as follows:
• Description of the MSG-RCV function in ladder program
• Parameter list setting of the MSG-RCV function
Note: IN: Input, OUT: Output, SYS: For system use
Table G.32 Parameter List Setting
Register Num-
ber
Setting
Value
Parameter Num-
ber
IN/OUT
Remarks
DW00000
–
PARAM00
OUT
Process result
DW00001
–
PARAM01
OUT
Status
DW00002
00001
PARAM02
IN
Connection number = 1
DW00003
–
PARAM03
OUT
Option (setting unnecessary)
DW00004
–
PARAM04
OUT
Function Code
DW00005
–
PARAM05
OUT
Data address
DW00006
–
PARAM06
OUT
Data size
DW00007
–
PARAM07
OUT
Remote CPU number
DW00008
00000
PARAM08
IN
Coil offset = 0 word
DW00009
00000
PARAM09
IN
Input relay offset = 0 word
DW00010
00000
PARAM10
IN
Input register offset = 0 word
DW00011
01000
PARAM11
IN
Holding register offset = 1000 words
DW00012
00000
PARAM12
IN
Write range LO = 0
DW00013
65534
PARAM13
IN
Write range HI = 65534
DW00014
–
PARAM14
SYS
Reserved (zero clear at startup)
DW00015
–
PARAM15
SYS
Reserved
DW00016
–
PARAM16
SYS
Reserved
Execute
Communication device = 218IFA
Protocol = MEMOBUS
Circuit number = 1
Communication buffer channel number = 1
Parameter list start address = DA00000
(use DW00000-DW00016)
Abort
Dev-Typ
Pro-Typ
Cir-No
Ch-No
Param
MSG-RCV
Busy
Complete
Error
DB000201
DB000202
00016
00001
00001
DA00000
00001
DB000210
DB000211
DB000212