6.4 Communication with PLC Manufactured by Mitsubishi Electric Corporation (MELSEC protocol)
6.4.1 When the MP2300S Acts as Slave (automatic receive function is used)
6-81
Built-in Ethernet Communications
( 2 ) How to Set up the Remote Device (MELSEC Q series) to Be Connected
This section explains the MELSEC Q series side procedure to set up for connecting the MP2300S with the MELSEC Q
series.
Note: MELSEC Q series are manufactured by Mitsubishi Electric Corporation.
Contact Mitsubishi Electric Corporation for more information.
1.
Start up GX Developer.
2.
Create a new project.
3.
Set up network parameters (MELSECNET/Ethernet).
4.
Set up Ethernet operation.
5.
Set the open setting.
Table 6.22 Network Parameter Setting (example)
Setting Item
Setting Details
Network Type
Ethernet
Start I/O No.
Any
Network No.
Any
Group No.
Any
Exchange Number
Any
Mode
Online
Table 6.23 Ethernet Operation Setting (example)
Setting Item
Setting Details
Communication Data Code
Setting
Binary code communication
Initial Timing Setting
Any
IP Address
192.168.1.2
Transmit Frame Setting
Ethernet (V2.0)
TCP Alive Check Setting
Any
Permit Writing during RUN
Permitted
Table 6.24 Open Setting (example)
Setting Item
Setting Details
(connection number=1)
Protocol
TCP
Open System
Active
Fixed Buffer
Transmit
Procedure to Communicate with Fixed Buffer
With procedure
Pairing Open
Any
Check Alive
Any
Local Port Number
2711H (10001)
Remote IP Address for Communications
192.168.1.1
Remote Port Number for Communications
2711H (10001)