beautypg.com

Yaskawa MP2300S Basic Module User Manual

Page 149

background image

5.2 User Programs

5.2.2 Motion Programs

5-16

„

Timing Chart for Motion Program Control Signals

The following figure shows an example of a timing chart for motion program control signals.

Œ

An alarm will occur if the stop request is turned ON during axis operation using a motion command.

[ c ] Interpolation Override

The override when executing interpolation travel commands (setting; unit: 1 = 0.01%) is set.
This interpolation override is enabled only when the motion program control signal bit E (interpolation override set-
ting) is ON.

Control signal: Operation start request

Status: Operating

Distribution

One scan

Program Operation Start Request

Control signal: Operation start request

Status: Operating

Distribution

Control signal: Pause request

Status: Paused

Pause Request

One scan

One scan

Control signal: Operation start request

Status: Operating

Distribution (MOV)

Control signal: Stop request

Distribution (MVS)

Status: Stopped

Status: Alarm

Stop Request

Control signal: Alarm clear