A-96, 4 ) connection number (param02) – Yaskawa MP2300S Basic Module User Manual
Page 418

Appendix G MSG-SND/MSG-RCV Functions (Ethernet)
G.2 Message Receive Function (MSG-RCV)
A-96
[ d ] PARAMETER (parameter)
When RESULT(process result) = 4 (FMT_NG: parameter format error), an error code in the table below is output. Oth-
erwise, the connection number is output.
( 4 ) Connection Number (PARAM02)
Specify the remote source.
When the communication device is Ethernet (218IF or 218IFA), set the connection number.
The following table shows the setting range.
Note: When the communication device is Ethernet (218IF or 218IFA), set the connection number in accor-
dance with the connection number in the 218IF or 218IFA Parameter Setting Window for the MPE720
module configuration definition.
Fig. G.10 218IFA Parameter Setting Screen for the MPE720 Module Configuration Definition Window
RESULT (process result)
Code (Hex)
Meaning
When RESULT (process re-
sult) =4
(FMT_NG: parameter format
error)
00
No error
01
Connection number is out of range
02
Time error for monitoring to receive MEMOBUS response
03
Error in setting retransmit count
04
Error in setting cyclic area
05
CPU number error
06
Data address error
07
Data size error
08
Function code error
Others
xx
Connection number
Communication Device
Connection
Number
Remarks
Ethernet (218IF)
1 to 20
Receives from the remote station set for the specified connection number.
Ethernet (218IFA)
1 to 4
Same as above