3 registers, 1 types of registers, 1 ) dwg registers – Yaskawa MP2300S Basic Module User Manual
Page 168

5.3 Registers
5.3.1 Types of Registers
5-35
Outline of Motion Control Systems
5.3 Registers
This section describes the types of registers used in MP2300S user programs (mainly ladder programs) and how to use
them.
5.3.1 Types of Registers
( 1 ) DWG Registers
Registers used by ladder programs (ladder drawings; DWG). Each drawing can use the registers outlined in the follow-
ing table.
Note: 1. n: Decimal number; h: Hexadecimal number
2. B, W, L, F, and A: Data type (B: Bit, W: Integer, L: Double-length integer, F: Real number, A: Address.
Refer to 5.3.2 Data Types.)
3. Up to 32 D registers (32 words, DW0000 to DW0031) can be used when creating drawings, but this
can be changed in the MPE720 Drawings Properties Window. Refer to the Machine Controller MP900/
MP2000 Series MPE720 Software for Programming Device User’s Manual (manual number: SIEP
C880700 05) or, refer to Engineering Tool for MP2000 Series Machine Controller MPE720 Version 6
User’s Manual (manual number: SIEP C880700 30) for details.
4. S and M register data has a battery backup to ensure the data is held even if the MP2300S power is
turned OFF and ON. Other register data is saved to flash memory, so when the MP2300S power is
turned OFF to ON, data saved to flash memory is read and data not saved to flash memory is lost.
It is recommended, therefore, that data to be held regardless of whether or not the power is turned
OFF to ON should be written to M registers if possible.
Type
Name
Specification Method
Range
Details
Characteristics
S
System registers SB, SW, SL, SFnnnnn
(SAnnnnn)
SW00000 to
SW08191
Registers provided by the system. SW00000 to
SW00049 are cleared to all zeros when the sys-
tem starts.
Common to all
drawings
M
Data registers
MB, MW, ML,
MFnnnnn
(MAnnnnn)
MW00000 to
MW65534
Registers shared by all drawings. Used, e.g., as
an interface between drawings.
I
Input registers
IB, IW, IL, IFhhhh
(IAhhhh)
IW0000 to
IW13FFF
Registers used for input data.
O
Output registers
OB, OW, OL, OFhhhh
(OAhhhh)
OW0000 to
OW13FFF
Registers used for output data.
C
Constants regis-
ters
CB, CW, CL, CFnnnnn
(CAnnnnn)
CW00000 to
CW16383
Registers that can only be called from programs.
#
# registers
#B, #W, #L, #Fnnnnn
(#Annnnn)
#W00000 to
#W16383
Call-only registers Can be called only by corre-
sponding drawing. The usage range is set by the
user using MPE720.
Unique to each
drawing
D
D registers
DB, DW, DL,
DFnnnnn
(DAnnnnn)
DW00000 to
DW16383
Internal registers unique to each drawing. Can be
used only by corresponding drawing.
The usage range is set by the user using
MPE720.