2 how to determine slave cpu synchronous state, 1 ) how to check with a master side application, 2 ) how to check with a slave side application – Yaskawa MP2300S Basic Module User Manual
Page 293

7.3 Operation
7.3.2 How to Determine Slave CPU Synchronous State
7-15
Slave CPU Synchronous Function
7.3.2 How to Determine Slave CPU Synchronous State
The way to determine the slave CPU synchronous state from an application program is as follows:
( 1 ) How to Check with a Master Side Application
Use bit 7 “SYNC” of the second word “Slave Status” (IW + 1) of an input register assigned to MP2300S.
If SYNC = ON, it is in a slave CPU synchronous state.
( 2 ) How to Check with a Slave Side Application
Use bit7 “SYNC” of the second word “Slave Status” (IW + 1) of an input register assigned to a local station.
If SYNC = ON, it is in a slave CPU synchronous state.
bit7
Bit6
bit5
bit4
bit3
bit2
bit1
bit0
SYNC
SYNCRDY
SBUSY
0
CMDRDY
WARNG
0
Data 1
High
Low
IW
+0
IW
+1
IW
+2
7 6 5 4 3 2 1 0
MP2000 (master)
[Input register]
Scan counter
used by system
Slave status
used by system
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
SYNC
SYNCRDY
SBUSY
0
CMDRDY
WARNG
0
ᧂ↪
IW
+0
IW
+1
IW
+2
7 6 5 4 3 2 1 0
MP2300S (slave)
[Input register]
Scan counter
unused
Slave status
unused
Data 1
High
Low