beautypg.com

A-24 – Yaskawa MP2300S Basic Module User Manual

Page 346

background image

Appendix B SERVOPACK Parameter Data Flow

B.1 Operations and Parameter Data Flow

A-24

( 5 ) Copying Current Values to Set Values (Input Data) in the SERVOPACK Tab

The data flow for SERVOPACK parameters is as follows when selecting Edit - Copy Current Value from the SERVO-
PACK
Tab in the SVB Definition Window on the MPE720:

1.

The MPE720 copies the values currently displayed in Current Value to Input Data on the SERVO-
PACK
Tab and displays.

MECHATROLINK

RAM

EEP

-ROM

SRAM

SDRAM

MP2300S

SERVOPACK

SERVOPACK

Control

Software

System

Software

Parameters

Servo Parameters

(All Axes)

Flash

Memory

Input

Data

MPE720

㧔online㧕

HDD in personal computer

Display

Current

Value

Input

Data