beautypg.com

A-37 – Yaskawa MP2300S Basic Module User Manual

Page 359

background image

Appendix E Motion Parameter Details

E.1 Fixed Parameter List

A-37

Appendices

30

Encoder Selection

0: Incremental Encoder
1: Absolute Encoder
2: Absolute Encoder (Incremental encoder is used.)
3: Reserved

Yes

31 to 33

Reserved

34

Rated Motor Speed
(Rotary Motor)

1 = 1 min

-1

Yes

Yes

Rated Speed
(Linear Type)

1 = 0.1 m/s, 0.1 mm/s

Yes

Yes

36

Number of Pulses per Motor
Rotation (Rotary Motor)

1 = 1 pulse/rev
Set the value after multiplication.

Yes

Yes

Number of Pulses per Linear
Scale Pitch (Linear Type)

1 = 1 pulse/scale pitch

Yes

Yes

38

Maximum Number of Absolute
Encoder Turns Rotation

1 = 1 rotation

• Set to 0 when a direct drive motor is being used.
• Invalid for linear type.

Yes

40 to 41

Reserved

42

Feedback Speed Movement Av-
eraging Time Constant

1 = 1 ms

Yes

Yes

(cont’d)

Slot

Number

Name

Contents

SVB SVR