2 ) alarm list for the sgds servopack – Yaskawa JAPMC-MC2300 User Manual
Page 353

12.4 Troubleshooting Motion Errors
12.4.3 Analog Servo Alarm List
12-34
( 2 ) Alarm List for the SGDS SERVOPACK
: Alarm displayed
×: No alarm displayed
Code
Alarm Name
Alarm Content
A.020
Parameter Checksum Error
The SERVOPACK's internal parameter data is incorrect.
A.021
Parameter Format Error
The SERVOPACK's internal parameter data is incorrect.
A.022
System Checksum Error
The SERVOPACK's internal parameter data is incorrect.
A.023
Parameter Password Error
The SERVOPACK's internal parameter data is incorrect.
A.030
Main Circuit Detector Error
There was an error in the power circuit's detection data.
A.040
Parameter Setting Error
A parameter setting exceeds the allowed setting range.
A.041
Divided Pulse Output Setting
Error
The PG Dividing Ratio (Pn212) setting violates the allowed setting range
or setting conditions.
A.042
Parameter Combination Error
The combination of several parameter settings exceeds the allowed setting
range.
A.050
Combination Error
The Servomotor and SERVOPACK capacity settings are incompatible.
A.051
Unsupported Product Alarm
An incompatible Serial Converter Unit is connected.
A.0b0
Servo ON Reference Invalid Alarm After using the Operator to perform an operation that turns the Servo ON, a
Servo ON reference was attempted by a host command.
A.100
Overcurrent or
Heat Sink Overheat
An overcurrent flowed through the IGBT or the SERVOPACK's heat sink
overheated.
A.300
Regeneration Error
The Regenerative Resistor is disconnected or the Regenerative Transistor
failed.
A.320
Regeneration Overload
The regenerative energy exceeds the Regenerative Resistor's capacity.
A.330
Main Circuit Wiring Error
The power supply method used to supply the main circuit does not match
the setting in parameter Pn001.
A.400
Overvoltage
The main circuit's DC voltage is excessively high.
A.410
Undervoltage
The main circuit's DC voltage is too low.
A.510
Overspeed
The Servomotor's speed is too high.
A.511
Divided Pulse Output Overspeed
The motor speed calculated from the PG Dividing Ratio (Pn212) exceed
the motor's upper limit speed.
A.520
Oscillation Alarm
Excessive oscillation was detected in the motor speed.
A.521
Autotuning Alarm
There was an error in the moment of inertia ratio calculation during auto-
tuning.
A.710
Overload
(Instantaneous Maximum Load)
The motor operated with a torque that significantly exceeds the rated torque
for several seconds to several dozen seconds.
A.720
Overload
(Continuous Maximum Load)
The motor is operating continuously at a torque exceeding the rated torque.
A.730
DB Overload
During DB (Dynamic Braking) operation, the rotating energy exceeds the
DB resistor's capacity.
A.740
Inrush Resistance Overload
The main circuit power supply was turned OFF and ON repeatedly.
A.7A0
Heat Sink Overheat
The SERVOPACK’s heat sink overheated.
A.810
Encoder Backup Alarm
The encoder power supplies are all down and the position data was cleared.
A.820
Encoder Checksum Alarm
A checksum error was detected in the encoder's memory.
A.830
Encoder Battery Alarm
The voltage is too low in the absolute encoder's backup battery.
A.840
Encoder Data Alarm
The encoder's internal data is incorrect.
A.850
Encoder Over Speed
The encoder was rotating at high-speed when the power was turned ON.
A.860
Encoder Overheat
The encoder's internal temperature is too high.
A.b10
Speed Reference A/D Error
There is an error in the speed reference input's A/D converter.
A.b11
Speed Reference A/D Data Error
There is an error in the speed reference's A/D converter data.
A.b20
Torque Reference A/D Error
There is an error in the torque reference input's A/D converter.
A.b31
Current Detection Error 1
There is an error in the phase-U current sensor.
A.b32
Current Detection Error 2
There is an error in the phase-V current sensor.
A.b33
Current Detection Error 3
There is an error in the current sensor.