3 switching from ex_posing – Yaskawa JAPMC-MC2300 User Manual
Page 234

8.1 Switchable Motion Commands
8.1.3 Switching from EX_POSING
8-7
8
Switching Commands during Execution
8.1.3 Switching from EX_POSING
Switched From
Switched To
Operation
EX_POSING
NOP
EX_POSING will switch to NOP when the axis stops after deceleration.
POSING
EX_POSING will immediately switch to POSING. The moving amount stored in the
accel/decel filter will be reset to 0.
The value of Position Reference Setting (OL
1C) when the motion command is
switched will be as follows. 09, bit 5 = 0)> Incremental value = Target position − IL 14 (DPOS) OL 1C = OL 1C + Incremental value 09, bit 5 = 1)> OL 1C = Target position EX_POSING EX_POSING operation will continue. ZRET EX_POSING will switch to ZRET when the axis stops after deceleration. EX_POSING Cancelled EX_POSING operation EX_POSING NOP EX_POSING NOP Motion command response EX_POSING Cancelled EX_POSING operation EX_POSING POSING EX_POSING POSING The speed will smoothly change. The speed at the time the motion command is switched will increase/decrease until it reaches the POSING target speed. The accel/decel filter will remain valid. POSING Motion command response EX_POSING EX_POSING Motion command response ZRET EX_POSING ZRET ZRET Cancelled EX_POSING operation
Motion command
Motion command
Motion command