7 switching from feed – Yaskawa JAPMC-MC2300 User Manual
Page 244

8.1 Switchable Motion Commands
8.1.7 Switching from FEED
8-17
8
Switching Commands during Execution
8.1.7 Switching from FEED
Switched From
Switched To
Operation
FEED
NOP
FEED will switch to NOP when the axis stops after deceleration.
POSING
FEED will immediately switch to POSING, and the moving amount stored in the accel/
decel filter will be maintained.
The value of Position Reference Setting (OL
1C) when the motion command is
switched will be as follows.
09, bit 5 = 0)> Incremental value = Target position − IL 14 (DPOS) OL 1C = OL 1C + Incremental value 09, bit 5 = 1)> OL 1C = Target position EX_POSING FEED will immediately switch to EX_POSING, and the moving amount stored in the The value of Position Reference Setting (OL 1C) when the motion command is switched will be as follows. 09, bit 5 = 0)> Incremental value = Target position − IL 14 (DPOS) OL 1C = OL 1C + Incremental value 09, bit 5 = 1)> OL 1C = Target position FEED FEED NOP FEED NOP Motion command response FEED FEED Motion command response POSING FEED POSING The speed will smoothly change. The speed at the time the motion command is switched will increase/decrease until it reaches the POSING target speed. The accel/decel filter will remain valid. POSING FEED FEED Motion command response EX_POSING FEED EX_POSING The speed will smoothly change. The speed at the time the motion command is switched will increase/ decrease until it reaches the EX_POSING target speed. The accel/decel filter will remain valid. EX_POSING
accel/decel will be maintained.
Motion command
Motion command
Motion command