7.2 Motion Command Details
7.2.11 Phase References (PHASE)
7-83
7
Motion Commands
( 4 ) Timing Charts
[ a ] Normal Execution
[ b ] Execution when Aborted
IW
0C
Bit 3
NEAR Position
The operation depends on the setting of NEAR Signal Output Width (setting param-
eter OL
20).
OL
20 = 0:Turns ON when pulse distribution has been completed (DEN =
ON). Otherwise, it turns OFF.
OL
20
≠
0:Turns ON when the absolute value of the difference between
MPOS (IL
12) and APOS (IL
16) is less than the NEAR
Position Setting, even if pulse distribution has not been completed.
OFF in all other cases.
(cont’d)
Parameter
Name
Monitor Contents
OW
08 = 25 (PHASE)
IW
08 = 25 (PHASE)
IW
09, bit 0 (BUSY)
IW
09, bit 8 (COMPLETE)
IW
09, bit 3 (FAIL)
IW
0C, bit 0 (DEN)
IW
0C, bit 1 (POSCOMP)
Undefined length of time
1 scan
The speed reference value is automatically refreshed every scan.
Position control mode
Phase control mode
Undefined length of time
Position control mode
Phase control mode
IW
0C, bit 1 (POSCOMP)
1 scan
OW
08 = 25 (PHASE)
IW
09, bit 0 (BUSY)
IW
08 = 25 (PHASE)
IW
09, bit 3 (FAIL)
IW
0C, bit 0 (DEN)
IW
09, bit 8 (COMPLETE)
The speed reference is refreshed every scan.
Speed control mode