1 system startup flowchart – Yaskawa JAPMC-MC2300 User Manual
Page 275

10.2 Setting Procedure of Absolute Position Detection Function
10.2.1 System Startup Flowchart
10-4
10.2 Setting Procedure of Absolute Position Detection Function
This section explains the procedure for setting the Absolute Position Detection Function.
10.2.1 System Startup Flowchart
Start up the system using the following procedure.
* If the system does not satisfy the conditions described in 10.4.1 ( 2 ) Conditions to Enable the Simple Absolute Infi-
nite Axis Position Control on page 10-14 when using the axis as an infinite length axis, the Machine Controller car-
ries out the operation without using simple absolute length position control.
After the steps 2 to 4 described above are successfully completed, the absolute position detection system will be ready
for operation.
Always perform the startup procedure of the absolute position detection system in the following situations.
• When starting up the absolute position detection system for the first time
• When the Servomotor is changed
• When an absolute encoder-related alarm occurs
1
Check Devices
Check to see if the SERVOPACK, Servomotor, and cables are the right products and models for the absolute encoder.
2
Initialize the Absolute Encoder
Follow the setup procedure to set the absolute encoder to default values.
(
→ 10.2.2 Initializing the Absolute Encoder on page 10-5, and Appendix B Initializing the Absolute Encoder on page A-
5)
3
Setting Parameters Related to the Machine Controller and the SERVOPACKs
Set all parameters related to the Absolute Position Detection Function of the Machine Controller and SERVOPACKs.
The setting procedure for a finite length axis is different from that for an infinite length axis.
When using the axis as a Finite
Length Axis
→ 10.3.1 Parameter Settings for
Finite Length Axes on page 10-6
→ 10.3.2 Detailed Descriptions on
Parameter Settings for Finite
Length Axes on page 10-8
When using the axis as an Infinite Length Axis
→ 10.4.1 ( 2 ) Conditions to Enable the Simple Absolute Infinite Axis Position
Control on page 10-14
*
With simple absolute infinite length
position control
→ 10.4.2 Parameters Setting for Sim-
ple Absolute Infinite Length Posi-
tion Control on page 10-16
Without simple absolute infinite
length position control
*
→ 10.4.6 Infinite Length Position
Control without Simple Absolute
Positions on page 10-22
4
Zero Point Setting
Set the zero point as well as the absolute zero point, that is, the machine coordinate zero point.
The setting procedure for a finite length axis is different from that of an infinite length axis.
When using the axis as a Finite
Length Axis
→ 10.3.3 Setting the Zero Point for a
Finite Length Axis on page 10-10
With simple absolute infinite length
position control
→ 10.4.4 Setting the Zero Point and
Turning ON Power as Simple
Absolute Positions on page 10-20
Without simple absolute infinite
length position control
*
→ 10.4.6 ( 3 ) Setting the Zero Point
for an Infinite Length Axis without
Simple Absolute Positions on page
10-22