5 switching from interpolate – Yaskawa JAPMC-MC2300 User Manual
Page 240

8.1 Switchable Motion Commands
8.1.5 Switching from INTERPOLATE
8-13
8
Switching Commands during Execution
8.1.5 Switching from INTERPOLATE
Switched From
Switched To
Operation
INTERPOLATE
NOP
INTERPOLATE will immediately switch to NOP, and the moving amount stored in the
accel/decel filter will be maintained.
POSING
INTERPOLATE will immediately switch to POSING, and the moving amount stored in
the accel/decel filter will be maintained.
The value of Position Reference Setting (OL
1C) when the motion command is
switched will be as follows.
09, bit 5 = 0)> Incremental value = Target position − IL 14 (DPOS) OL 1C = OL 1C+ Incremental value 09, bit 5 = 1)> OL 1C = Target position EX_POSING Same as POSING ZRET INTERPOLATE will immediately switch to ZRET and the moving amount stored in the INTERPOLATE INTERPOLATE operation will continue. INTERPOLATE The amount stored in the accel/decel filter will be output. INTERPOLATE NOP INTERPOLATE NOP Motion command response INTERPOLATE INTERPOLATE POSING INTERPOLATE POSING POSING The speed will smoothly change. The speed at the time the motion command is switched will increase/decrease until it reaches the POSING target speed. The accel/decel filter will remain valid. Motion command response ZRET INTERPOLATE INTERPOLATE Motion command response ZRET INTERPOLATE ZRET The distribution of moving amount stored in the accel/decel filter will be cancelled.
accel/decel filter will be reset to 0.
Motion command
Motion command
Motion command