8 zero point setting (zset), 1 ) executing/operating procedure, 2 ) holding and aborting – Yaskawa JAPMC-MC2300 User Manual
Page 211: 3 ) related parameters

7.2 Motion Command Details
7.2.8 Zero Point Setting (ZSET)
7-71
7
Motion Commands
7.2.8 Zero Point Setting (ZSET)
The ZSET command sets the current position as the zero point of the machine coordinate system. This enables setting
the zero point without performing a zero point return operation.
When using software limits, always execute the zero point setting or zero point return operation. The software limit
function will be enabled after the zero point setting operation has been completed.
( 1 ) Executing/Operating Procedure
1.
Check to see if all the following conditions are satisfied.
2.
Set OW
08 to 9 to execute the ZSET motion command.
A new machine coordinate system will be established with the current position as the zero point. IW
08 will
be 9 during the zero point setting operation. IW
0C, bit 5 will turn ON when zero point setting has been com-
pleted.
3.
Set OW
08 to 0 to execute the NOP motion command and then complete the zero point setting.
( 2 ) Holding and Aborting
The Holds A Command bit (OW
09, bit 0) and the Interrupt A Command bit (OW
09, bit 1) cannot be used.
( 3 ) Related Parameters
[ a ] Setting Parameters
[ b ] Monitoring Parameters
No.
Execution Conditions
Confirmation Method
1
There are no alarms.
IL
04 is 0.
2
Motion command execution has been completed.
IW
08 is 0 and IW
09, bit 0 is OFF.
Parameter
Name
Setting
OW
08
Motion Command
Set to 9 for ZSET command.
OW
09
Bit 0
Holds A Command
This parameter is ignored for ZSET command.
OW
09
Bit 1
Interrupt A Command
This parameter is ignored for ZSET command.
OL
48
Zero Point Position in
Machine Coordinate
System Offset
Sets the position offset from the zero point in the machine coordinate system after the
setting of the zero point has been completed.
Parameter
Name
Monitor Contents
IL
02
Warning
Stores the most current warning.
IL
04
Alarm
Stores the most current alarm.
IW
08
Motion Command
Response Code
Indicates the motion command that is being executed.
The response code is 9 during ZSET command execution.
IW
09
Bit 0
Command Execution
Flag
Turns ON during ZSET command execution and turns OFF when ZSET command exe-
cution has been completed.
IW
09
Bit 1
Command Hold
Completed
Always OFF for ZSET command.
IW
09
Bit 3
Command Error
Completed Status
Turns ON if an error occurs during ZSET command execution.
Turns OFF when another command is executed.
IW
09
Bit 8
Command Execution
Completed
Turns ON when ZSET command execution has been completed.
IW
0C
Bit 5
Zero Point Return
(Setting) Completed
Turns ON when the setting of the zero point has been completed.