2 basic system configuration, 1 list of basic units – Yaskawa MP930 User Manual
Page 56

2.2 Basic System Configuration
2 -31
2.2 Basic System Configuration
This section gives an overview of the system configuration used by the MP930, together with the
various devices in this configuration.
2.2.1 List of Basic Units
Table 2.12 lists of the Units and other devices required in a system using the MP930.
Table 2.12 List of Basic Units and Equipment
No.
Name
Description
Outline
1
MC Unit
MC350
Performs sequence and motion control.
2
I/O Unit
IO350
Expansion I/O Unit
IN: 64 points, OUT: 64 points
3
MECHATROLINK
Cable 1
W6000
Used to expand the MC Unit.
Connected to the I/O Unit.
4
MECHATROLINK
Cable 2
W6010
Connects the Expansion I/O Unit (or MC Unit)
and servo amp.
5
MC Unit I/O Cable
W5410
Connects the MC Unit and an external device.
6
Expansion I/O Unit
I/O Cable
W5410
Connects the Expansion I/O Unit and an exter-
nal device.
7
Servopack
SGD-jjjN
SGDB-jjAN
Select a MECHATROLINK-compatible servo.
8
Servomotor
−
Select from a number of Series.
9
Motor Cable
DP320081
Power cable for motor
10
Encoder Cable
DB320089
Connects the motor encoder and the servo amp.
11
Software Package
−
Motion program and ladder logic program cre-
ation, etc.
12
Communications
Cable
W5311
Connects the MC Unit and Programming De-
vice.
13
DC power supply
−
24 VDC power supply for the MC Unit, Ex-
pansion I/O Unit, and external I/O signals