Parameters
5.2.2 Setting Parameters
5 -28
Parameter
No.
Name
Register
No.
Description
Default
37
Workpiece coordinate
offset
OLxx2E
This parameter stores offset when a POS motion command is
specified.
S
Setting range: −2
31
to 2
31
− 1 (1 = 1 reference unit)
0
38
Preset No. of POSMAX
turns
OLxx30
With an infinite length axis, a turn is counted every time the posi-
tion value exceeds POSMAX and the count is stored at monitor
parameter ILxx1E: No. of POSMAX turns.
The number of turns can be preset by turning ON setting parame-
ter OWxx32D b1: Preset request for the number of POSMAX.
S
Setting range: −2
31
to 2
31
− 1 (1 = 1 reference unit)
Related Parameters
S
Fixed parameter 22: Maximum value for an infinite length
counter
S
Setting parameter OWxx2D b1: Preset data for the number of
POSMAX turns
S
Monitor parameter ILxx1E: Number of POSMAX turns.
0
39
Second in-position width OWxx32
Turns ON monitor parameter b2: Second INP completed if the
difference between the reference position and the feedback posi-
tion after distribution has been completed is within the range set
for this parameter.
The parameter can be set using an INP motion command.
S
Setting range: 0 to 65535 (1 = 1 reference unit)
0
40
Zero point output width
OWxx33
Turns to position control status IWxx17 b1, ZERO = ON if the
absolute value for the machine coordinate system reference posi-
tion (MPOS) is within the zero point position output width
OWxx33 after the machine returns to the zero point (motion com-
mand status IWxx15 b6, ZRNC = ON).
0
Zero point
Z
Z
MPOS
S
Setting range: 0 to 65535 (1 = 1 reference unit)
Related Parameters
S
Monitor parameter ILxx17 b1: Zero point position
5