beautypg.com

6 starting the cp-717 – Yaskawa MP930 User Manual

Page 141

background image

4.3 System Startup Methods

4 -39

4.3.6 Starting the CP-717

This section explains the Units configuring the MP930, the I/O allocation module configura-
tion definitions, and the methods of setting the group definitions for the number of axes and
tasks. Be sure to set these when the system is first started up.

Make sure the CP-717 System Software is installed in advance.

The following is an overview of the CP-717 startup procedure.

1. Creation of an Order Folder

2. Creation of a PLC Folder

3. Offline Logon

4. Module Configuration Definitions

5. Group Definitions

6. Scan Time Settings

J

Creation of an Order Folder

Start the CP-717, and create an order folder from the File Manager Screen.

D

Example:

File name: DEMO

1. Point to root, right click, and then click New Make (N) New Make Order Folder (O).

2. In the dialog box, input the order folder name and click the OK button. The order folder

name must be eight characters or less.

3. The new “DEMO” order folder will be created.

4