Yaskawa MP930 User Manual
Page 194

5.1 Description of Parameters
5 -9
No.
Default Setting
Range
Units
Size
Name
Cn-001F
First level linear acceleration/deceleration time
constant
2
1,000 reference
units/s
2
0-65535
0
Cn-0020
Second level linear acceleration/deceleration time
constant
2
10,000 reference
units/s
2
0-65535
100
Cn-0021
Acceleration/decelerationtimeconstantswitching
speed
2
1,000 reference
units/s
0-65535
0
Cn-0022
Zero point return approach speed 1
2
1,000 reference
units/s
0-65535
50
Cn-0023
Zero point return approach speed 2
2
1,000 reference
units/s
0-65535
5
Cn-0024
Electronic gear ratio, numerator
2
1-32768
4
Cn-0025
Electronic gear ratio, denominator
2
1-32768
1
Cn-0026
Average move time
2
100 µs
0-5100
0
Cn-0027
Feed forward reference filter
2
µs
0-64000
0
Cn-0028
Final distance traveled to zero point return
4
reference units
−2147483648 to
2147483647
100
Cn-002A
Zero point position range
2
reference units
0-65535
10
Cn-002B
Final distance traveled to external positioning
4
reference units
−2147483648 to
2147483647
100
Cn-002D
Exponential acceleration speed bias
2
reference units/s
0-32767
0
Cn-002E
Exponential acceleration time constant
2
100 µs
0-5100
0
Cn-002F
Forward direction software limit
4
reference units
−2147483648
to 2147483647
8192 × 99999
Cn-0031
Reverse direction software limit
4
reference units
−2147483648
to 2147483647
8192 × 99999
Cn-0033
Absolute encoder zero point position offset
4
reference units/s
−2147483648
to 2147483647
0
Cn-0035
−
2
−
−
0000H
Cn-0036
Reserved by system.
2
−
−
0000H
Cn-0037
Motor selection (SGDB only)
2
−
0 to 255
255
Cn-0038
PG power supply voltage change (SGDB only)
2
0.1 mV
52000 to 58000
52500
Cn-0039
Reserved by system.
2
−
−
0000H
Cn-003A
Reserved by system.
2
−
−
0000H
Cn-003B
Reserved by system.
2
−
−
0000H
Cn-003C
Reserved by system.
2
−
−
0000H
Cn-003D
Reserved by system.
2
−
−
0000H
Cn-003E
Reserved by system.
2
−
−
0000H
Cn-003F
Reserved by system.
2
−
−
0000H
5