Yaskawa MP930 User Manual
Page 219

Parameters
5.2.3 Monitor Parameters
5 -34
No.
Remarks
Description
Register
No.
Name
17
Position control status
IWxx17
These flags indicate position control status.
−
b0: MLKL
Machine lock ON
−
b1: ZERO
Zero point position
S
Turns ON when MPOS (machine coor-
dinate system reference position) moves
from the machine coordinate system zero
point to within the preset range set at set-
ting parameter OWxx33 (zero point
position output width) at completion of
zero point return.
−
b2: PSET2
Second INP complete
S
Turns ON when the difference between
the reference position and the feedback
position after completing distribution is
within the range set at setting parameter
OWxx32: Second in-position width.
−
b3: ABSLDE
ABS system infinite position control data
LOAD complete
−
b4: TPRSE
Preset request for the no. of POSMAX turns
completed
−
b5: GEARM
Copy enabled electronic gear selection
−
b6: MODSELM
Copy axis selection
−
b12 to b15: USR-
MONSERL
MECHATROLINK servo user monitor data
selection response
S
Stores the type of monitor data stored at
monitor parameter ILxx20: MECHA-
TROLINK servo user monitor data.
−
18
Reference position in the ma-
chine coordinate system
ILxx18
This is the reference position for the machine coordinate system
and it is essentially the same as ILxx02 (CPOS). MPOS does not
equal CPOS because the position is not updated when the ma-
chine is locked.
−
20
POSMAX monitoring
ILxx1C
Stores the POSMAX value set at fixed parameter 22 and is used
when motion and other functions use POSMAX for reference.
−
21
No. of POSMAX turns
ILxx1E
The count goes up and down every time POSMAX is exceeded
when using an infinite length rotating axis.
−
22
Monitor data for the servo
drive user
ILxx20
Stores monitor data for the MECHATROLINK servo selected at
setting parameter OWxx2D b12 to b15:MECHATROLINK servo
monitor data selection. See the Σ-Series SGMj/SGD-jN User’s
Manual (SIE-S800-26.3) for more details.
−
5