5.1.2 Parameter Lists
5 -6
J
Monitor Parameters
No.
Name
Register
No.
Setting
Range
Meaning
Remarks
1
Operating status
IWxx00
Set by bit
−
−
2
MECHATROLINK servo status
IWxx01
Set by bit
−
−
3
Calculated position monitored in
the machine coordinate system
ILxx02
−2
31
to 2
31
−1
1 = 1 reference unit
CPOS
4
−
ILxx04
−
Not used.
−
5
Latch position monitored in the
machine coordinate system
ILxx06
−2
31
to 2
31
−1
1 = 1 reference unit
LPOS
6
Feedback position monitored in
the machine coordinate system
ILxx08
−2
31
to 2
31
−1
1 = 1 reference unit
APOS
7 to 10
−
IWxx0A to
IWxx0E
−
Not used.
−
11
Parameter No. out of range
IWxx0F
1 to 47
101 to 127
−
−
12, 13
−
IWxx10 to
IWxx13
−
Not used.
−
14
Motion command response code IWxx14
0 to 65535
Motion command currently executing. −
15
Motion command status
IWxx15
Set by bits
−
−
16
No. of digits left of radix point
IWxx16
0 to 5
Same as fixed parameter 18.
−
17
Position control status
IWxx17
Set by bit
−
−
18
Reference position in the ma-
chine coordinate system
ILxx18
−2
31
to 2
31
−1
1 = 1 reference unit
MPOS
19
−
ILxx1A
−
Not used.
−
20
POSMAX monitoring
ILxx1C
1 to 2
31
−1
1 = 1 reference unit
21
No. of POSMAX turns
ILxx1E
−2
31
to 2
31
−1
1 = 1 rotation
22
Monitor data for the servo drive
user
ILxx20
−2
31
to 2
31
−1
−
−
23
Alarm
ILxx22
Set by bits
Servo-related alarms
−
24
Servo driver alarm code
IWxx24
Servo Amp alarm codes
−
25
Servo driver I/O monitoring
IWxx25
Set by bits
−
−
26
Speed reference output monitor-
ing
ILxx26
−2
31
to 2
31
−1
1 = 1 reference unit/s, pulse/s
−
27
MECHATROLINK servo user
constant monitoring
ILxx28
−2
31
to 2
31
−1
−
−
5