D.3 monitor parameter number 23 alarms – Yaskawa MP930 User Manual
Page 329

D.3 Monitor Parameter Number 23 Alarms
D -5
D.3 Monitor Parameter Number 23 Alarms
The following table shows the servo-related alarms for each axis.
Register
Number
Bit
Alarm Name
Cause
Action
ILxx22
b0: SVERR Servopack error
S
A SERVOPACK alarm was de-
tected.
S
See IWxx24 for the alarm details.
S
Check for Servopack errors.
S
Contact your Yaskawa representa-
tive if the problem recurs even af-
ter the Servopack is reset.
b1: OTF
Forward overtravel
S
Forward overtravel of the Servo-
pack was detected (P-OT signal
ON).
S
Check the overtravel limit switch,
and bring it back in the opposite
direction after resetting the alarm.
S
Check the overtravel input signal.
S
Check the parameters relating to
overtravel alarm detection.
b2: OTR
Reverse overtravel
S
Reverse overtravel of the Servo-
pack was detected (N-OT signal
ON).
S
Check the overtravel limit switch,
and bring it back in the opposite
direction after resetting the alarm.
S
Check the overtravel input signal.
S
Check the parameters relating to
overtravel alarm detection.
b3: SOTF
Stored positive stroke
limit
S
Movement towards the positive
stored stroke limit area was de-
tected.
S
After checking the program and
operation, reset the alarm and
bring the switch back in the oppo-
site direction.
S
Check the parameters relating to
the stored stroke limit.
b4: SOTR
Stored negative
stroke limit
S
Movement towards the negative
stored stroke limit area was de-
tected.
S
After checking the program and
operation, reset the alarm and
bring the switch back in the oppo-
site direction.
S
Check the parameters relating to
the stored stroke limit.
b5: SVOFF Servo power OFF
S
A move command was generated,
but the servo power was OFF.
S
After resetting the alarm, turn ON
the servo power.
b6:
TIMEOVER
Positioning time ex-
ceeded
S
After the command was executed,
positioning could not be com-
pleted in the time set in OWxx34
(“positioning completion check
time”).
S
Check the parameters relating to
the servo characteristics (each type
of gain).
S
Check the connections between
the Servopack and motors.
D