C.2 setting parameter list – Yaskawa MP930 User Manual
Page 321

C.2 Setting Parameter List
C -3
C.2 Setting Parameter List
The following table shows a list of the setting parameters.
No.
Name
Register
Number
Setting Range
Meaning
Initial Value
1
Operation mode setting
OWxx00
Set for each bit
2
Servo drive operation reference set-
ting
OWxx01
Set for each bit
3 to 6
Not used
7
Zero point offset setting
OLxx06
0 to ±2
31
−1
1 = 1 reference unit
0
8 to 10
Not used
11
Linear acceleration time setting
OWxx0C
0 to 32767
1 = 1 ms
0
12 to 14 Not used
15
Position loop gain setting
OWxx10
1 to 32767
1 = 0.1/S
400
16
Feed forward gain setting
OWxx11
0 to 200
1 = 1%
0
17
Position reference pulse setting
OLxx12
−2
31
to 2
31
−1
1 = 1 reference unit
0
18
Average rotation setting
OWxx14
0 to 65535
1 = 1 ms
0
19
Speed reference setting
OWxx15
0 to ±32767
1 = 0.01%
0
20 to 25 Not used
26
Speed loop gain setting
OWxx1D
1 to 32767
1 = 0.1 HZ
400
27
Not used
28
Motion command code
OWxx20
0 or more
Command number desig-
nated for servo amplifier
29
Motion command control flag
OWxx21
Set for each bit
30
Rapid traverse speed
OLxx22
0 to 2
31
−1
1 = 10
n
reference unit/min
(n: Number of digits after the
decimal point)
0
31
External positioning travel distance
OLxx24
−2
31
to 2
31
−1
1 = 1 reference unit
0
32
Stopping distance
OLxx26
−2
31
to 2
31
−1
1 = 1 reference unit
0
33
STEP travel distance
OLxx28
0 to 2
31
−1
1 = 1 reference unit
1000
34
Zero point return final travel distance OLxx2A
−2
31
to 2
31
−1
1 = 1 reference unit
0
35
Override
OWxx2C
0 to 32767
1 = 0.01%
10000
36
Position control flag
OWxx2D
37
Work coordinate offset
OLxx2E
-2
31
to 2
31
-1
1 = 1 reference unit
0
38
Preset data of number of POSMAX
turns
OLxx30
-2
31
to 2
31
-1
1 = 1 reference unit
0
39
Second in-position width
OWxx32
0 to 65535
1 = 1 reference unit
0
C