Parameters

5.2.3 Monitor Parameters

5 -36

No.

Remarks

Description

Register

No.

Name

23

Alarms (continued)

ILxx22

b9: FILTIMERR

Filter time constant change error

S

The filter time constant was changed be-
fore distribution was completed.

b10: MODERR

Control mode error

S

A Position Control Mode motion com-
mand was used in a mode other position
control.

b11:
ZSET_NRDY

Zero point not set

S

The zero point is not set and a move ref-
erence was executed without setting the
zero point.

b12:

Not used.

b13:

Not used.

b14: WDT_ERR

MECHATROLINK servo synchronized
communications error

S

The MP930 detected a synchronized
communications error with the ME-
CHATROLINK servo.

Servo
OFF

b15: COM_ERR

MECHATROLINK servo communications
error

S

The MP930 detected a communications
error two consecutive times with the
MECHATROLINK servo.

Servo
OFF

b16: SVTIMOUT

MECHATROLINK servo command time-
out error

S

A MECHATROLINK servo command
was not completed within the specified
time.

Servo
OFF

b17: ABSOVER

ABS encoder rotation count exceeded

S

The number of ABS encoder rotations
exceeded the range of the MP930.

b18 to b31

Not used.

24

MECHATROLINK servo
alarm code

IWxx24

This parameter is used to monitor alarm codes generated by the
MECHATROLINK servo. See the Σ-Series SGMj/SGD-jN
User’s Manual
(SIE-S800-26.3) for more details. Normally 99H
is monitored.