Functions of the TNC 640 and the iTNC 530 compared 19.5

19

TNC 640 | User's Manual
HEIDENHAIN Conversational Programming | 5/2013

645

Cycle

TNC 640

iTNC 530

440, measuring an axis shift

X

441, Rapid probing (on TNC 640 partly possible with touch probe
table)

X

450, saving the kinematics

X, option 48

X, option 48

451, measuring the kinematics

X, option 48

X, option 48

452, preset compensation

X, option 48

X, option 48

460, calibrating a TS on a sphere

X

X

461, calibrate TS length

X

X

462, calibration in a ring

X

X

463, calibration on stud

X

X

480, calibrating a TT

X

X

481, measuring/inspecting the tool length

X

X

482, measuring/inspecting the tool radius

X

X

483, measuring/inspecting the tool length and radius

X

X

484, calibrating the infrared TT

X

X

Comparison: Differences in programming

Function

TNC 640

iTNC 530

Switching the operating mode
while a block is being edited

Not permitted

Permitted

File handling:

Save file

function

Available

Available

Save file as

function

Available

Available

Discard changes

Available

Available

File management:

Mouse operation

Available

Available

Sorting function

Available

Available

Entry of name

Opens the

Select file pop-up

window

Synchronizes the cursor

Support of shortcuts

Not available

Available

Favorites management

Not available

Available

Configuration of column
structure

Not available

Available

Soft-key arrangement

Slightly different

Slightly different

Skip block function

Available

Available

Selecting a tool from the table

Selection via split-screen menu

Selection in a pop-up window

Programming special functions
with the SPEC FCT key

Pressing the key opens a soft-key
row as a submenu. To exit the
submenu, press the SPEC FCT
key again; then the TNC shows
the last active soft-key row

Pressing the key adds the soft-key
row as the last row. To exit the
menu, press the SPEC FCT key
again; then the TNC shows the
last active soft-key row