beautypg.com

Setting handshaking (flowcontrol), File system for file operations (filesystem), Mod functions 18.8 setting up data interfaces – HEIDENHAIN TNC 640 (34059x-02) User Manual

Page 592

background image

MOD functions

18.8 Setting up data interfaces

18

592

TNC 640 | User's Manual

HEIDENHAIN Conversational Programming | 5/2013

Setting handshaking (flowControl)

By handshaking, two devices control data transfer between them.
A distinction is made between software handshaking and hardware
handshaking.

No data flow checking (NONE): Handshaking is not active

Hardware handshaking (RTS_CTS): Transmission stop is active
through RTS

Software handshaking (XON_XOFF): Transmission stop is active
through DC3 (XOFF)

File system for file operations (fileSystem)

In

fileSystem you define the file system for the serial interface.

This machine parameter is not required if you don't need a special
file system.

EXT: Minimum file system for printers or non-HEIDENHAIN
transmission software. Corresponds to the EXT1 and EXT2
modes of earlier TNC controls.

FE1: Communication with the TNCserver PC software or an
external floppy disk unit.

Settings for data transfer with the TNCserver PC
software

Enter the following settings in the user parameters
(

serialInterfaceRS232 / definition of data blocks for the serial

ports / RS232

):

Parameters

Selection

Data transfer rate in baud

Has to match the setting
in TNCserver

Data transmission protocol

BLOCKWISE

Data bits in each transferred
character

7 bits

Type of parity checking

EVEN

Number of stop bits

1 stop bit

Specify type of handshake:

RTS_CTS

File system for file operations

FE1