Select kinematics, Mod functions 18.2 machine settings – HEIDENHAIN TNC 640 (34059x-02) User Manual
Page 586
MOD functions
18.2 Machine settings
18
586
TNC 640 | User's Manual
HEIDENHAIN Conversational Programming | 5/2013
If you assign the access right
Query to a connection and access is
implemented from this address, the TNC opens a pop-up window.
You must permit or deny external access in the pop-up window:
External access
Permission
Yes
Permit once
Always
Permit continuously
Never
Deny continuously
No
Deny once
In the overview list an active connection is shown
with a green symbol.
Connections without access rights are shown gray in
the overview list.
Machine-dependent function: You can permit
or restrict access for external diagnostics or
commissioning software with the TNCOPT soft key.
Select kinematics
The
Select Kinematics function must be enabled and
adapted by the machine manufacturer.
Refer to your machine manual.
You can use this function to test programs whose kinematics
does not match the active machine kinematics. If your machine
manufacturer saved different kinematic configurations in your
machine, you can activate one of these kinematics configurations
with the MOD function. When you select a kinematics model for
the test run this does not affect machine kinematics.
Danger of collision!
When you switch the kinematics model for machine
operation, the TNC implements all of subsequent
movements with modified kinematics.
Ensure that you have selected the correct kinematics
in the test run for checking your workpiece.