beautypg.com

HEIDENHAIN TNC 640 (34059x-02) User Manual

Page 374

background image

Programming: Special functions

11.2

Dynamic Collision Monitoring (software option)

11

374

TNC 640 | User's Manual

HEIDENHAIN Conversational Programming | 5/2013

Deactivating collision monitoring

If you have to reduce the distance between collision-monitored
objects for lack of space, the collision monitoring function can be
deactivated.

Danger of collision!

If you deactivate collision monitoring, the TNC does
not output an error message with a pending collision.
With inactive collision monitoring the symbol for
collision monitoring in the operating mode bar starts
to blink:

In addition, the TNC shows a corresponding symbol
in the position display (see the table below).

Symbols in the status display show the condition of collision
monitoring:

Function

Symbol

Collision monitoring active

Collision monitoring is not available

Collision monitoring is not active

Shift the soft-key row if necessary

Select the menu for deactivating collision
monitoring

Select the

Manual Operation menu item

To deactivate collision monitoring, press the ENT
key, and the symbol for collision monitoring in the
operating mode display starts to blink

Move axes manually, pay attention to traverse direction

To reactivate the collision monitor: Press the ENT key