How to add remote panel modules to a network, How to change ethernet settings – Grass Valley CRSC v.3.2 User Manual
Page 40

28
Ethernet Settings Page
Usage
How to Add Remote Panel Modules to a Network
Follow these steps to add remote panel modules to your network:
1 Connect up to 15 remote panel modules to the network with unique rotary switch settings
in the range 1 to F.
2 Go to the ‘CR Series Ethernet Settings’ page.
3 Verify that all added remote panel modules appear in the list.
4 For each remote panel module, click on the cell in the ‘IP Address’ column to edit the field.
Enter a unique IP address according to the following formulas:
5 Repeat steps 1 through 4 for additional remote panel modules.
6 Click Apply Updates to send the changes to the selected frames. Only those frames with
‘Update’ checked in the table rows are updated. The data are stored in the frames internally.
How to Change Ethernet Settings
1 Go to the ‘CR Series Ethernet Settings’ page.
2 Locate the router or remote panel module you want to update.
3 In that row, click the cell you want to change: the IP address, subnet mask or gateway IP
address. The field opens for editing.
4 Type in the new value.
We recommend that you leave the subnet masks at 255.255.255.0.
5 To record your change, press ‹enter
›
or ‹tab›, or click in another field. Press ‹Esc› to cancel
your change.
6 Repeat steps 2–5 for additional changes. The ‘Update’ check box automatically displays a
check mark if you update any of the information.
7 Click
Apply Updates
to send the changes to the selected frames. Only those frames with
‘Update’ checked in the table rows are updated. The data are stored in the frames internally.
Remember to cycle power after you change a rotary switch.
However, if a rotary switch is set to zero (0), and you then power-cycle the router or
remote panel module, the device reverts to the factory default state, and loses its previ-
ously configured state.