How to Convert a Remote Panel Module

1 Go to the ‘NV9000 Remote Panel Settings’ page.

2 In the ‘Remote Panel’ tab, click the radio button on the row listing the remote panel module

to be converted.

3 Check the ‘Enable NV9000 Mode’ check box to convert the remote panel module to use with

an NV9000 control system.

Uncheck the ‘Enable NV9000 Mode’ check box to revert the remote panel module to use in a
CRSC network.

4 If you have enabled NV9000 mode, enter a panel ID in the ‘NV9000 Panel ID’ field.

The panel ID must be a number unique within the NV9000 system. It must contain no special
characters, spaces, or punctuation marks.

By default, the panel ID is composed of the last two octets of the module’s current IP
address. For example, if its IP address is 192.168.97.21, then the default panel ID is 97021.

5 If you have enabled NV9000 mode, check the ‘Use DHCP to acquire IP Address’ check box if

you want the NV9000 system to use DHCP to determine the remote panel module’s IP
address. Otherwise, the panel’s IP address will be fixed in the NV9000 system and will retain
its present IP address.

6 Click Update Remote Panel to complete the conversion.

All CR Frames

Name

Name assigned to the frame.

Frame Type

Type (model number) of frame.

IP Address

IP address currently assigned to the frame.

Subnet Mask

Subnet mask currently assigned to the device.

Tab

Column

Description