NewTek TriCaster 8000 User Manual
Page 309
Page | 293
By default, third-party products generally support the AirSend commands discussed
next, included in the NewTek product macro system.
C
LIP
_S
TORE
Delay (ms)
Shortcut
Value
Key 1
Value 1
(ms)
net1 or net2 clip_store
index
ID
This command stores a custom local reference ID for the current clip (the one
currently visible at on the network input). The value ID can be a string. ID is global
and shared across your system (it is not stored per system output, if you have
multiple).
For example:
Delay (ms)
Shortcut
Value
Key 1
Value 1
.0001
net1
clip_store
index
AAA1
The entry above will ‘remember’ the current clip with the name “AAA1”. (The
default for ID is an empty string, which is a valid storage target.)
C
LIP
_R
ESTORE
Delay (ms)
Shortcut
Value
Key 1
Value 1
(ms)
net1 or net2 clip_restore
index
ID
This command cues up content previously stored with a specified ID value on the
upstream source channel assigned to the network input designated.
For example:
Delay (ms)
Shortcut
Value
Key 1
Value 1
.0001
net1
clip_restore
index
AAA1