Page | 293

By default, third-party products generally support the AirSend commands discussed
next, included in the NewTek product macro system.

C

LIP

_S

TORE

Delay (ms)

Shortcut

Value

Key 1

Value 1

(ms)

net1 or net2 clip_store

index

ID


This command stores a custom local reference ID for the current clip (the one
currently visible at on the network input). The value ID can be a string. ID is global
and shared across your system (it is not stored per system output, if you have
multiple).

For example:

Delay (ms)

Shortcut

Value

Key 1

Value 1

.0001

net1

clip_store

index

AAA1

The entry above will ‘remember’ the current clip with the name “AAA1”. (The
default for ID is an empty string, which is a valid storage target.)

C

LIP

_R

ESTORE

Delay (ms)

Shortcut

Value

Key 1

Value 1

(ms)

net1 or net2 clip_restore

index

ID


This command cues up content previously stored with a specified ID value on the
upstream source channel assigned to the network input designated.

For example:

Delay (ms)

Shortcut

Value

Key 1

Value 1

.0001

net1

clip_restore

index

AAA1