beautypg.com

5 function select - remote aupc (optional), Remote aupc - configuration, Remote aupc - monitor – Comtech EF Data CIM-300L User Manual

Page 79

background image

CiM-300L IP Enabled Satellite Modem

Rev. 1

Front Panel Menus

CD/CIM300L.IOM

53

4.2.1.1.5 Function Select - Remote AUPC (Optional)

DISPLAY SELECTIONS/DESCRIPTION

FUNCTION SELECT

REMOTE AUPC


CONFIGURATION
MONITOR
Note: This is available ONLY with the

ASYNC/AUPC overhead option.

Remote AUPC - Configuration

DISPLAY SELECTIONS/DESCRIPTION

REMOTE AUPC

CONFIGURATION


AUPC ENABLE

ON


ON
OFF
Note: This program is for control of the last

known status.

B-BAND LOOPBACK

ON


ON
OFF
Note: This program is for control of the last

known status.

TX 2047 PATTERN

ON


ON
OFF
Note: This program is for control of the last

known status.

Remote AUPC - Monitor

DISPLAY SELECTIONS/DESCRIPTION

REMOTE AUPC

MONITOR


2047 ERRORS

No Data


Receive 2047 BER. This is a monitor point
that displays the current RX 2047 BER. If no
data is available,
“No Data” is displayed.