M snmp t – Comtech EF Data CIM-300L User Manual
Page 263
CiM-300L IP Enabled Satellite Modem
Rev. 1
SNMP
CD/CIM300L.IOM
237
11.4.1.8 C
I
M SNMP T
RAPS
The CiM-300L has the ability to send out SNMP traps when certain events occur in the
modem. For example, when the CiM-300L boots it sends out a coldstart trap and 3
linkup traps, one for each interface that is brought up. The CiM-300L also sends out
traps when an alarm or a fault occurs in the modem. These include unit faults, TX faults,
and RX faults. A trap is sent both when a fault occurs and is cleared.
The CiM-300L supports both SNMPv1 traps and SNMPv2 notifications. Which style of
traps the CiM-300L can be configured by the user using the cimSnmpTrapVersion OID.
The following are the MIB2 v1traps / v2 notifications that the CiM-300L supports.
CiM-300L MIB2 SNMPv1 traps:
Cold Start
1
Warm Start
2
Link Down
3
Link Up
4
Authentication Failure
5
CiM-300L MIB2 SNMPv2 notifications:
Cold Start
1.3.6.1.6.3.1.1.5.1
Warm Start
1.3.6.1.6.3.1.1.5.2
Link Down
1.3.6.1.6.3.1.1.5.3
Link Up
1.3.6.1.6.3.1.1.5.4
Authentication Failure
1.3.6.1.6.3.1.1.5.5
The following tables are the Alarms and Faults v1 traps / v2 notifications that the CiM-
300L supports.
CiM-300L Alarms and Faults SNMPv1 traps:
cim300LModulatorFaultsTrap 624761
cim300LdemodulatorFaultsTrap 624762
cim300LTxInterfaceFaultsTrap 624763
cim300LRxInterfaceFaultsTrap 624764
cim300LcommonEquipFaultsTrap 624765
cim300LoduFaultsTrap 624766