beautypg.com

M snmp t – Comtech EF Data CIM-300L User Manual

Page 263

background image

CiM-300L IP Enabled Satellite Modem

Rev. 1

SNMP

CD/CIM300L.IOM

237

11.4.1.8 C

I

M SNMP T

RAPS

The CiM-300L has the ability to send out SNMP traps when certain events occur in the
modem. For example, when the CiM-300L boots it sends out a coldstart trap and 3
linkup traps, one for each interface that is brought up. The CiM-300L also sends out
traps when an alarm or a fault occurs in the modem. These include unit faults, TX faults,
and RX faults. A trap is sent both when a fault occurs and is cleared.
The CiM-300L supports both SNMPv1 traps and SNMPv2 notifications. Which style of
traps the CiM-300L can be configured by the user using the cimSnmpTrapVersion OID.
The following are the MIB2 v1traps / v2 notifications that the CiM-300L supports.
CiM-300L MIB2 SNMPv1 traps:

Cold Start

1

Warm Start

2

Link Down

3

Link Up

4

Authentication Failure

5

CiM-300L MIB2 SNMPv2 notifications:

Cold Start

1.3.6.1.6.3.1.1.5.1

Warm Start

1.3.6.1.6.3.1.1.5.2

Link Down

1.3.6.1.6.3.1.1.5.3

Link Up

1.3.6.1.6.3.1.1.5.4

Authentication Failure

1.3.6.1.6.3.1.1.5.5

The following tables are the Alarms and Faults v1 traps / v2 notifications that the CiM-
300L supports.
CiM-300L Alarms and Faults SNMPv1 traps:

cim300LModulatorFaultsTrap 624761

cim300LdemodulatorFaultsTrap 624762

cim300LTxInterfaceFaultsTrap 624763

cim300LRxInterfaceFaultsTrap 624764

cim300LcommonEquipFaultsTrap 624765

cim300LoduFaultsTrap 624766