Table 11-40. utility parameters oids – Comtech EF Data CIM-300L User Manual

Page 281

background image

CiM-300L IP Enabled Satellite Modem

Rev. 1

SNMP

CD/CIM300L.IOM

255

11.5.1.5 U

TILITY

P

ARAMETERS

Table 11-40. Utility Parameters OIDs

OID Description

cim300LOduPower

Can be set to:

0 Off

1 On

cim300LOduPower

Can be set to:

0 Off

1 On

cim300LOduThresholdLow

Range is 0 and 4000 in 100 mA steps.

cim300LOduThresholdHigh

Range is 0 and 4000 in 100 mA steps.

cim300LLnbPower

Can be set to:

0 Off

1 On

cim300LLnbVoltage

Can be set to:

13 13

Volts

18 18

Volts

24 24

Volts

cim300LLnbRefEnable

Can be set to:

0 Off

1 On

cim300LLnbThresholdLow

LNB Power Monitor Low Current Threshold. The value can
be between 0 and 500 in 1 mA steps.

cim300LLnbThresholdHigh

LNB Power Monitor High Current Threshold. The value can
be between 0 and 500 in 1 mA steps.

cim300LCarrierOnlyMode

Can be set to:

0 None

1 Dual

3 Offset

4 Center

cim300LIfLoopBack

Can be set to:

0 Off

1 On