Table 8-2. aupc default settings – Comtech EF Data CIM-300L User Manual
Page 152
CiM-300L IP Enabled Satellite Modem
Rev. 1
AUPC
CD/CIM300L.IOM
126
To setup the modem for the self-monitoring operation, enter the Local Modem AUPC
menu located under the Utility Modem Type menu and select On. This enables the
Configuration: Local AUPC menu to permit adjustment of the AUPC parameters
described in Table 8-1.
Notes:
1
Comtech EF Data does not recommend increasing the power to the satellite without
consulting with the satellite controller.
2
Be careful not to set carrier output too high when there is a loss of carrier due to
severe weather and the CL loss action is set to Maximum.
3
Do not use the distant end RX signal to compensate for local rain fade unless
allowances are made for a narrow window for TX level changes.
8.1.4 F
RONT
P
ANEL
O
PERATION
For information on the additional front panel operations that are specific to the ASYNC
interface. The following menus are affected:
!
Configuration Local AUPC
!
Remote AUPC Configuration
!
Remote AUPC Monitor
Table 8-2. AUPC Default Settings
Local AUPC
AUPC ENABLE
OFF
Target Noise
6.0 dB
Nominal Power
+0.0 dBm
Tracking Rate
0.5 dB/MIN
Minimum Power
-20.0 dBm
Local CL Action
Hold
Maximum Power
+5 dBm
Remote CL Action
Hold