Comtech EF Data CIM-300L User Manual
Page 119
CiM-300L IP Enabled Satellite Modem
Rev. 1
Serial Remote Control
CD/CIM300L.IOM
93
141
142
143
144
145
(ref. “LNBV_” command).
LNB Reference
(ref. “LNBR_” command).
LNB Current Monitor Low Threshold
(ref. “LNBL_” command).
LNB Current Monitor High Threshold
(ref. “LNBH_” command).
P141 = n, where 'n' is '0' (off) or '1' (on).
P142 = n, where ‘n’ is ‘0’ (13 Volts), ‘1’ (18 Volts), or ‘2’ (24
Volts.
P143 = n, where ‘n’ is ‘0’ (OFF) or ‘1’ (ON).
P144 = nnn, where ‘nnn’ is 0 to 500 in 1 mA steps
P145 = nnn, where ‘nnn’ is 0 to 500 in 1 mA steps
Notes:
1.
Data will only be returned if TX Overhead is programmed for Drop & Insert. Comma is always returned for CiM-300L.
2.
Data will only be returned if RX Overhead is programmed for Drop & Insert. Comma is always returned for CiM-300L.
3.
Data will only be returned if TX Overhead is programmed for IDR. Comma is always returned for CiM-300L.
4.
Data will only be returned if RX Overhead is programmed for IDR. Comma is always returned for CiM-300L.
5.
Data will only be returned if TX Overhead is programmed for ASYNC. Comma is always returned for CiM-300L.
6.
Data will only be returned if RX Overhead is programmed for ASYNC. Comma is always returned for CiM-300L.
7.
Data is only returned if FLEX MUX PCB (Card Slot #1) is installed. Comma is always returned for CiM-300L.
8.
Data not returned if TX Channel #1 is disabled. Comma is always returned for CiM-300L.
9.
Data not returned if TX Channel #3 is disabled or set for AUPC. Comma is always returned for CiM-300L.
10.
Data not returned if TX Channel #4 is disabled or set for AUPC. Comma is always returned for CiM-300L.
11.
Data not returned if RX Channel #1 is disabled. Comma is always returned for CiM-300L.
12.
Data not returned if RX Channel #3 is disabled or set for AUPC. Comma is always returned for CiM-300L.
13.
Data not returned if RX Channel #4 is disabled or set for AUPC. Comma is always returned for CiM-300L (except for last
parameter).
14.
Data will only be returned if TX Overhead is programmed for ASYNC. (or TX Flex Mux AUPC). Comma is always returned for CiM-
300L.
15.
Data will only be returned if RX Overhead is programmed for ASYNC. (or RX Flex Mux AUPC). Comma is always returned for CiM-
300L.