beautypg.com

Comtech EF Data CIM-300L User Manual

Page 119

background image

CiM-300L IP Enabled Satellite Modem

Rev. 1

Serial Remote Control

CD/CIM300L.IOM

93


141


142


143


144


145

(ref. “LNBV_” command).

LNB Reference
(ref. “LNBR_” command).

LNB Current Monitor Low Threshold
(ref. “LNBL_” command).

LNB Current Monitor High Threshold
(ref. “LNBH_” command).

P141 = n, where 'n' is '0' (off) or '1' (on).


P142 = n, where ‘n’ is ‘0’ (13 Volts), ‘1’ (18 Volts), or ‘2’ (24
Volts.

P143 = n, where ‘n’ is ‘0’ (OFF) or ‘1’ (ON).


P144 = nnn, where ‘nnn’ is 0 to 500 in 1 mA steps


P145 = nnn, where ‘nnn’ is 0 to 500 in 1 mA steps


Notes:
1.

Data will only be returned if TX Overhead is programmed for Drop & Insert. Comma is always returned for CiM-300L.

2.

Data will only be returned if RX Overhead is programmed for Drop & Insert. Comma is always returned for CiM-300L.

3.

Data will only be returned if TX Overhead is programmed for IDR. Comma is always returned for CiM-300L.

4.

Data will only be returned if RX Overhead is programmed for IDR. Comma is always returned for CiM-300L.

5.

Data will only be returned if TX Overhead is programmed for ASYNC. Comma is always returned for CiM-300L.

6.

Data will only be returned if RX Overhead is programmed for ASYNC. Comma is always returned for CiM-300L.

7.

Data is only returned if FLEX MUX PCB (Card Slot #1) is installed. Comma is always returned for CiM-300L.

8.

Data not returned if TX Channel #1 is disabled. Comma is always returned for CiM-300L.

9.

Data not returned if TX Channel #3 is disabled or set for AUPC. Comma is always returned for CiM-300L.

10.

Data not returned if TX Channel #4 is disabled or set for AUPC. Comma is always returned for CiM-300L.

11.

Data not returned if RX Channel #1 is disabled. Comma is always returned for CiM-300L.

12.

Data not returned if RX Channel #3 is disabled or set for AUPC. Comma is always returned for CiM-300L.

13.

Data not returned if RX Channel #4 is disabled or set for AUPC. Comma is always returned for CiM-300L (except for last
parameter).

14.

Data will only be returned if TX Overhead is programmed for ASYNC. (or TX Flex Mux AUPC). Comma is always returned for CiM-
300L.

15.

Data will only be returned if RX Overhead is programmed for ASYNC. (or RX Flex Mux AUPC). Comma is always returned for CiM-
300L.