CiM-300L IP Enabled Satellite Modem

Rev. 1

Front Panel Menus

CD/CIM300L.IOM

38

DISPLAY SELECTIONS/DESCRIPTION

TRACKING RATE

Programs the maximum tracking rate of
the AUPC.
Maximum tracking rate can range from
0.5 to 6.0 dBm/minute, in 0.5 dBm/minute
steps.
Upon entry, the current maximum
tracking rate is displayed. Press [

↑] or [↓]

to increment or decrement the digit at the
flashing cursor. Press [ENTER] to
execute the change.

LOCAL CL ACTION

Programs the local carrier loss for HOLD,
NOMINAL, or MAXIMUM.
Upon entry, the status of the local carrier
loss is displayed. Press [

↑] or [↓] to make

the selection. Press [ENTER] to execute
the change.


REMOTE CL ACTION

Programs the remote carrier loss for HOLD,
NOMINAL, or MAXIMUM.
Upon entry, the status of the remote carrier
loss is displayed. Press [

↑] or [↓] to make the

selection. Press [ENTER] to execute the
change.

Configuration - Save

DISPLAY SELECTIONS/DESCRIPTION

CONFIGURATION

SAVE


CONFIGURATION #1

SAVE


The Configuration Save menu allows
programming of configuration parameters into
memory on the M&C. There are five memory
locations that may be used to store specific
configuration setups that are used frequently.
After changing the configuration parameters
to the desired settings, enter the
Configuration Save menu and select memory
location 1 through 5. Press [ENTER] to
execute the save.