CD/CIM300L.IOM

96

Bit 5 = Monitor & Control Module.
Bit 4 = Interface Module.
Bit 3 through Bit 0 = Binary representation (0 to 10) of the number of
common equipment stored faults.

Character 'o': Common equipment fault status character 2.
Bit 6 = 1 always.
Bit 5 = Battery/Clock.
Bit 4 = +5V power supply.
Bit 3 = reserved.
Bit 2 = +12V power supply.
Bit 1 = -12V power supply.
Bit 0 = reserved.

Character 'p': Interface backward alarm status character 1.
Bit 6 = 1 always.
Bit 5 = TX Backward Alarm 1.
Bit 4 = TX Backward Alarm 2.
Bit 3 through Bit 0 = Binary representation (0 to 10) of the number of
backward alarm stored faults.

Character 'q': Interface backward alarm status character 2.
Bit 6 = 1 always.
Bit 5 = TX Backward Alarm 3.
Bit 4 = TX Backward Alarm 4.
Bit 3 = RX Backward Alarm 1.
Bit 2 = RX Backward Alarm 2.
Bit 1 = RX Backward Alarm 3.
Bit 0 = RX Backward Alarm 4.

Character 'r': Interface Reed-Solomon Unavailable Seconds
Bit 6 = 1 always.
Bit 5 = not used.
Bit 4 = not used.
Bit 3 through Bit 0 = Binary representation (0 to 10) of the number of
Reed-Solomon Unavailable Seconds stored faults.

Change
Status

Command:
Response:

>add/CS_x'cr''lf']

Where:

The 'x' character is defined as follows:

'@' = no change since last BCS_ and BCSF_ polls.

'A' = BCS_ response has changed since last BCS_ poll.

'B' = BCSF_ response has changed since last BCSF_ poll.

'C' = Both responses have changed since last BCS_ and BCSF_
polls.

This command indicates that a change has or has not occurred on
either the BCS_ or the BCSF_ response since the last BCS_ or
BCSF_ poll.

Equipment
Type

Command:
Response:

>add/ET_tttttttt_xxx.yyy.zzz'cr''lf']

Where:
tttttttt = Equipment type (CiM300L-X)
xxx.yyy.zzz = Software version.