Cim 2 configuration, Verification, 9 verification – Comtech EF Data CIM-300L User Manual
Page 502: M 2 c, Ip a
CiM-300L IP Enabled Satellite Modem
Rev. 1
Cim IP Module Checkout
CD/CIM300L.IOM
476
12.2.8
C
I
M 2 C
ONFIGURATION
Disconnect RJ-11 end of the console cable from CiM 1 and connect it to CiM 2.
12.2.8.1 S
ETTING
IP A
DDRESS
(
ES
)
Step Description
1
From the Main Menu select Network Configuration sub-menu.
2
Set Ethernet IP Address to 172.17.10.10.
3
Set Subnet Prefix Length to 24.
4
Set HDLC IP Address to 10.1.1.2.
5
Set RX – Enable/Disable and TX – Enable/Disable to Enable.
6
From Receive HDLC Channel Address menu set HDLC Addr 1 to 1 (0x0001)
The other parameters can be left to their factory default settings. At this point you should
be able to ping CiM 2 from PC 2:
7
ping 172.17.10.10
8
ping 10.1.1.2
12.2.8.2 R
OUTE
T
ABLE
Step Description
1
From Transmitter Configuration, sub-menu select Route Table sub-menu.
2
Enter 1 to configure the first route
3
Enter a suitable name
4
Set IP Address to 172.16.10.0
5
Set Number of Subnet Bits to 24
6
Enter the next hop IP address which is CiM 1’s HDLC IP Address, 10.1.1.1
12.2.8.3 S
AVE
C
ONFIGURATION
Save parameters to permanent storage.
12.2.9 V
ERIFICATION
At this point the basic configuration is over and you should be able to:
!
Ping PC 1 from PC 2 and vice versa
!
Ping CiM 2 from PC 1 and vice versa
!
Pass any other data between the 2 PCs