beautypg.com

Stored faults, 6 stored faults – Comtech EF Data CIM-300L User Manual

Page 109

background image

CiM-300L IP Enabled Satellite Modem

Rev. 1

Serial Remote Control

CD/CIM300L.IOM

83

5.6 S

TORED

F

AULTS

Information on stored faults is returned when requested. If no stored fault exists for a given fault
number, the words “NO Fault” will be returned instead of the normal time/date status
information.

The following symbols are commonly used to define the stored faults status commands:

!

# Fault number (0 to 9). “0” is the first fault stored.

!

hh

Hours in 24-hr. format.

!

mm Minutes.

!

ss

Seconds.

!

MM Month.

!

DD Day.

!

YYYY Year.

Parameter

Type

Protocol

Description

Modulator
Stored Faults

Command:
Response:

>add/MSF_# hh:mm:ss
MM/DD/YYYYY'cr'
MOD_xxx'cr'
SYN_xxx'cr'
DCS_xxx'cr'
ICH_xxx'cr'
QCH_xxx'cr'
AGC_xxx'cr'
SCT_xxx'cr'
EXT_xxx'cr'
CONF_xxx'cr''lf']



Module (OK/FLT)
IF Synthesizer (OK/FLT)
Data Clock Synthesizer (OK/FLT)
I Channel (OK/FLT)
Q Channel (OK/FLT)
AGC Level (OK/FLT)
Modem Reference PLL Lock (OK/FLT)
Modem Reference Activity (OK/FLT)
Configuration (OK/FLT)

Demodulator
Stored Faults

Command:
Response:

>add/DSF_# hh:mm:ss
MM/DD/YYYY'cr'
MOD_xxx'cr'
CD_xxx'cr'
SYN_xxx'cr'
ICH_xxx'cr'
QCH_xxx'cr'
BERT_xxx'cr'
CONF_xxx'cr''
LNB_xxx’cr’’lf’]



Demod Module (OK/FLT)
Carrier Detect (OK/FLT)
IF Synthesizer Lock (OK/FLT)
I Channel (OK/FLT)
Q Channel (OK/FLT)
BER Threshold (OK/FLT)
Configuration (OK/FLT)
LNB (OK/FLT)

Common
Equipment
Stored Faults

Command:
Response:

>add/CSF_# hh:mm:ss
MM/DD/YYYY'cr'
M&C_xxx'cr'
INT_xxx'cr'
BAT_xxx'cr'
+5_xxx'cr'
+12_xxx'cr'
-12_xxx'cr'
ST_xxx'cr''lf']



Monitor & Control Module (OK/FLT)
Data Interface/Overhead Module (OK/FLT)
Battery/Clock (OK/FLT)
+5 Vdc Power Supply (OK/FLT)
+12 Vdc Power Supply (OK/FLT)
-12 Vdc Power Supply (OK/FLT)
Self Test (OK/FLT)