1 remote port b configuration subgroup – Comtech EF Data CIM-300L User Manual
Page 273

CiM-300L IP Enabled Satellite Modem
Rev. 1
SNMP
CD/CIM300L.IOM
247
11.4.1.16.1 Remote Port B Configuration Subgroup
This subgroup defines the Remote Port B configuration.
Table 11-33. Remote Port B Configuration Subgroup OIDs
OID Description
cimRemotePortBDeviceAddress Defines the device address. Valid addresses are in the
range from 0 to 9999.
cimRemotePortBBaudRate
Defines the speed of the serial interface.
Can be set to:
1 1200
2 2400
3 4800
4 9600
5 19200
6 38400
cimRemotePortBFormat
Supports three configurations for the Remote Port B
interface. Each format defines a triple that describes the
data bits, parity, and stop bits.
Can be set to:
1 8-N-1 (8 data bits, no parity, 1 stop bit)
2 7-E-2 (7 data bits, even parity, 2 stop bits)
3 7-O-2 (7 data bits, odd parity, 2 stop bits)
cimRemotePortBInterface
Configures the UART to operate in one of three types of
physical RS-xxx interfaces {RS-232, RS-485, RS-485-4W}.
The OID can be set to:
1 RS-232
2 RS-485 2W
3 RS-485 4W