Comtech EF Data CIM-300L User Manual
Page 118
CiM-300L IP Enabled Satellite Modem
Rev. 1
Serial Remote Control
CD/CIM300L.IOM
92
Bulk Consol.
Status
(continued)
Parameter
Number
Parameter Name
(Command Reference)
Description
(Note 9)
(Note 9)
(Note 9)
(Note 7)
(Note 10)
(Note 10)
(Note 10)
(Note 7)
(Note 11)
(Note 7)
(Note 7)
(Note 12)
(Note 12)
(Note 12)
(Note 7)
(Note 13)
(Note 13)
(Note 13)
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
TX Flex Mux Channel #3 Data Rate
(ref. "TCDR_3" command).
TX Flex Mux Channel #3 Clock Phase
(ref. "TCCP_3" command).
TX Flex Mux Channel #3 Data Phase
(ref. "TCDP_3" command).
TX Flex Mux Channel #4 Enable
(ref. "TCEN_4" command).
TX Flex Mux Channel #4 Data Rate
(ref. "TCDR_4" command).
TX Flex Mux Channel #4 Clock Phase
(ref. "TCCP_4" command).
TX Flex Mux Channel #4 Data Phase
(ref. "TCDP_4" command).
RX Flex Mux Channel #1 Enable
(ref. "RCEN_1" command).
RX Flex Mux Channel #1 Data Rate
(ref. "RCDR_1" command).
RX Flex Mux Channel #2 Enable
(ref. "RCEN_2" command).
RX Flex Mux Channel #3 Enable
(ref. "RCEN_3" command).
RX Flex Mux Channel #3 Data Rate
(ref. "RCDR_3" command).
RX Flex Mux Channel #3 Clock
Phase
(ref. "RCCP_3" command).
RX Flex Mux Channel #3 Data Phase
(ref. "RCDP_3" command).
RX Flex Mux Channel #4 Enable
(ref. "RCEN_4" command).
RX Flex Mux Channel #4 Data Rate
(ref. "RCDR_4" command).
RX Flex Mux Channel #4 Clock
Phase
(ref. "RCCP_4" command).
RX Flex Mux Channel #4 Data Phase
(ref. "RCDP_4" command).
LNB Power
(ref. “LNB_” command).
LNB Voltage
p123 = nnnn.n, where 'nnnn.n' is the data rate in Kbps.
p124 = n, where 'n' is '0' (Normal) or '1' (Invert).
p125 = n, where 'n' is '0' (Normal) or '1' (Invert).
p126 = n, where 'n' is '0' (Disabled), '1' (Sync RS232), '2'
(Async RS232), '3' (Async RS485), or '4' (AUPC operation).
p127 = nnnn.n, where 'nnnn.n' is the data rate in Kbps.
p128 = n, where 'n' is '0' (Normal) or '1' (Invert).
p129 = n, where 'n' is '0' (Normal) or '1' (Invert).
p130 = n, where 'n' is '0' (Disabled), '1' (D&I), or '2' (T1/E1
operation).
p131 = nnnn.n, where 'nnnn.n' is the data rate in Kbps.
p132 = n, where 'n' is '0' (Disabled), '1' (Enabled).
p133 = n, where 'n' is '0' (Disabled), '1' (Sync RS422), '2'
(Async RS422), '3' (Sync RS232), '4' (Async RS232), or '5'
(AUPC operation).
p134 = nnnn.n, where 'nnnn.n' is the data rate in Kbps.
p135 = n, where 'n' is '0' (Normal) or '1' (Invert).
p136 = n, where 'n' is '0' (Normal) or '1' (Invert).
p137 = n, where 'n' is '0' (Disabled), '1' (Sync RS232), '2'
(Async RS232), '3' (Async RS485), or '4' (AUPC operation).
p138 = nnnn.n, where 'nnnn.n' is the data rate in Kbps.
p139 = n, where 'n' is '0' (Normal) or '1' (Invert).
p140 = n, where 'n' is '0' (Normal) or '1' (Invert).