Alarms connector and pinouts (j10), Rf output connector (cp1), External reference (cp2) – Comtech EF Data CIM-300L User Manual
Page 45: Table 2-7. a, Larms, Onnector and, Inouts, J10), 8 rf o, Cp1)
CiM-300L IP Enabled Satellite Modem
Rev. 1
Installation
CD/CIM300L.IOM
19
2.3.7 A
LARMS
C
ONNECTOR AND
P
INOUTS
(J10)
The alarm connector provides Form C contact closures for alarm reporting. The two
Form C summary fault contacts are Modulator and Demodulator.
The alarm connection is a 9-pin female D connector (J10) located on the rear panel of the
modem. Screw locks are provided for mechanical security on the mating connector. Refer
to Table 2-7 for pinout information.
Table 2-7
. A
LARMS
C
ONNECTOR AND
P
INOUTS
(J10)
Pin # Signal Function
Name
1
Alarm 1 is faulted
NO
2
COM
3
Alarm 1 is not faulted
NC
4
Alarm 2 is faulted
NO
5
COM
6
Alarm 2 is not faulted
NC
7
Alarm 3 is faulted
NO
8
COM
9
Alarm 3 is not faulted
NC
Notes:
1
Alarm 1 = Not used
2
Alarm 2 = TX
3
Alarm 3 = RX
2.3.8 RF O
UTPUT
C
ONNECTOR
(CP1)
L-Band Configuration: CP1 is a Type N connector for the TX IF signal. The output
impedance is 50
Ω and the output return loss is ≥ -15 dB. In normal operation, the output
will be a QPSK (Optional: OQPSK) or BPSK modulated result of the Data I/O connector
between 950 to 1750 MHz, in 100 Hz steps.
2.3.9 E
XTERNAL
R
EFERENCE
(CP2)
CP2 is a BNC connector for an EXT REF. The input impedance is 75
Ω. For normal
operation, the desired carrier signal level is
≥ 0 dB.
EXT REF frequencies are EXT 1, EXT 5, EXT 10, and EXT 20 MHz.