beautypg.com

Fill memory – Zilog Z8F0130 User Manual

Page 153

background image

UM013037-1212

Tools Menu

Zilog Developer Studio II – Z8 Encore!

User Manual

129

write the serial number to the Flash device and then write the hex file.

Use the following procedure if you want to use the serialization feature:

1. Select the Enable checkbox.

2. Select the Include Serial in Programming checkbox.

This option programs the serial number after the selected hex file has been written to
Flash.

3. Enter the start value for the serial number in the

Serial Value

field and select the

Dec

button for a decimal serial number or the

Hex

button for a hexadecimal serial number.

4. Enter the location you want the serial number located in the

Address Hex

field.

5. Select the number of bytes that you want the serial number to occupy in the

# Bytes

drop-down list box.

6. Enter the decimal interval that you want the serial number incremented by in the

Increment Dec (+/–)

field. If you want the serial number to be decremented, enter a

negative number. After the current serial number is programmed, the serial number is
then incremented or decremented by the amount in the

Increment Dec (+/–)

field.

7. Select the Erase Before Flashing checkbox.

This option erases the Flash before writing the serial number.

8. Click

Burn Serial

to write the serial number to the current device or click

Program

or

Program and Verify

to program the Flash memory with the specified hex file and

then write the serial number.

If you want to check a serial number that has already been programmed at an address, per-
form the following tasks:

1. Select the Enable checkbox.

2. Enter the address that you want to read in the

Address Hex

field.

3. Select the number of bytes to read from

# Bytes

drop-down list box.

4. Click

Read Serial

to check the serial number for the current device.

Fill Memory

Use this procedure to write a common value in all of the memory spaces in the specified
address range, for example, to clear memory for the specified address range. This opera-
tion actually flashes the device.

To fill a specified address range of memory, observe the following procedure.

1. Select the memory space in the

Space

drop-down list box.

2. Right-click in the list box to display the context menu.