4-2 Basic Settings and Advanced Settings

4-30

4

Set
ting V

a

rious

F

unct

ions

IB-E

Zero shift input

When the zero shift input is set to ON, the internal measurement value (R.V.) is shifted
(offset) to an arbitrary shift target value.

"3-7 Zero Shift Function (Shifting the Internal Measurement Value (R.V.))" (page 3-18)

Timing chart

Minimum input time

ON time: 2 ms
OFF time: 2 ms

Reset input

When the reset input is turned ON while using the hold function, the judgment value (P.V.)
in the held state is canceled and the value becomes [-----].

" 5. Hold Function" (page 4-14)

Timing chart

Minimum input time

ON time: 0.5 ms
OFF time: 0.5 ms

Internal measurement

value (R.V.)

Max. 6 ms

Min. 2 ms

Min. 2 ms

R.V. before shift

R.V. after shift

ON

OFF

Zero shift input

Judgment value (P.V.)
judgment output

Max. 0.5 ms

Min. 0.5 ms

Min. 0.5 ms

Before resetting

[- - - - - ]

ON

OFF

Reset input