Display Screen and Output

Normally, the judgment value (P.V.) is displayed on the main display (upper level).
This section describes the judgment output and analog output status when displays other
than numbers appear on the main display.

*1

The output mode of judgment output can be set to NO (Normally Open) or NC
(Normally Closed).

"4. Output Mode" (page 4-13)

*2

If [erC] (overcurrent error) returns, all judgment outputs are fixed to OFF.

*3

HI/GO/LO turn on simultaneously when the error output mode is the LX2 compatible
mode.

"17. Error Output Mode" (page 4-39)

*4

HI/GO/LO turn on simultaneously when the error output mode is the LX2 compatible
mode.

"17. Error Output Mode" (page 4-39)

Reference

The judgment indicator on the amplifier unit operates in the same way as
Normally Open regardless of the output mode setting.

"3-6 Setting the Tolerance Setting Value" (page 3-13)

Status

Amplifier

Control input

Control

output

Analog

output

Uppe

r le
v

el

m

ai

n

d

is

p

la

y

J

udg

m

e

nt

indic

a

tor

*1

T

im
ing /Re

se

t

Ba
nk
s

w

it

ching/

em
is

si

o

n

sto

p

Ze
ro-
shif
t

Adjus

t input

J

udg

m

e

nt

out
put

*1

Vo
lta

g

e

(c

urre

nt

)

va
lu

e

Measuring

Judgment

value

(P.V)

Measurement

results

Yes

Yes

Yes

Yes

Measurement

results

Voltage (current) for

measured value

No

measurement

value

-----

All OFF

Yes

Yes

No

Yes

All OFF

Analog voltage

output: 5.5 V fixed

Analog current

output:3.0 mA fixed

Out of display

range

FFFF

Only HI

lights

Yes

Yes

No

Yes

Only HIGH

output ON

Fixed to upper limit

of analog output

range (For 1-5 V,

fixed to 5 V)

(When upper limit <

lower limit: 1 V)

Out of display

range

-FFFF

Only LO

lights

Yes

Yes

No

Yes

Only LOW

output ON

Fixed to lower limit

of analog output

range (For 1-5 V,

fixed to 1 V)

(When upper limit <

lower limit: 5 V)

Setting

Setting

item

Follows

setting

details

During error:

No

Other than

error:

Yes

Yes

Out of the

measurement

range,

during error:

No

Other than the

above:

Yes

Yes

Follows

setting

details

Follows setting

details

During error

Error

display

HI/LO

simultaneously

light

*3

No

Yes

No

No

HIGH/LOW

output

simultaneously

ON

*4

Analog voltage

output: 5.5 V fixed

Analog current

output: 3.0 mA fixed

Overcurrent

error

ErC

All OFF

Yes

Yes

Out of the

measurement

range,

during error:

No

Other than the

above:

Yes

Yes

All OFF

Voltage (current) for

measured value

EEPROM

error

ErE

Measurement

results

Yes

Yes

Out of the

measurement

range,

during error:

No

Other than the

above:

Yes

Yes

Measurement

results

Voltage (current) for

measured value