KEYENCE IB Series User Manual
Page 27
2-2 Connecting and Mounting the Sensor Head
2-11
IB-E
2
Inst
all
at
ion and
Connec
tion
Attaching the sensor head cable connector (OP-87060)
Cut the sensor head cable to the required length and attach the new connector to use the
sensor. The connection method is the same for the transmitter and receiver.
1
Cut the cable to the required length and strip approx. 15 mm of insulation
from the end.
2
Insert each color coded cable into the same colored marked points on the
connector.
Each cable is secured temporarily when it is inserted completely.
3
Confirm that all the cables are inserted properly into the connector and
crimp them using pliers or a similar tool.
Point
Do not strip the core wire insulation.
Point
Once the connector has been installed, make sure to connect
it to the amplifier and confirm that the sensor operates
normally.
If the sensor head does not function properly, crimp the
connector again using pliers or a similar tool.
Once the connector is crimped, it cannot be reused.
Blue Black
White Brown
Insert further