Auto peak hold

When the internal measurement value (R.V.) goes beyond the specified trigger level, the
sampling begins. When it falls below the trigger level, the sampling finishes. When the
sampling finishes, the maximum internal measurement value (R.V.) during the sampling
period is held as a judgment value (P.V.).
The external input is not required.

*1

" 10. External Input" (page 4-29)

*2

After the power is turned on or reset is input, the judgment value (P.V.) is [-----] until
the judgment value (P.V.) is first held.

*3

While the timing input is ON, the sampling does not start. If the sampling is already in
process, it continues.

Trigger level setting screen

When the auto peak hold is set, the display goes to the trigger level setting screen.

Press the  /  button on the trigger level setting screen to specify the trigger level.

" 1. Measurement Mode" (page 4-8)

Reference

The operation by the timing input is the same regardless of the " 6. Timing
Input" (page 4-23) set
ting.

Display value

Time

Timing Input

Trigger level

Hysteresis

ON

OFF

Power ON or
Reset input*

1

*3

*2

Judgment value (P.V.)

Internal measurement
value (R.V.)

Item

Measurement

mode

Setting range

Default value

Trigger level

% mode

- 999.99 to 999.99

90.00

Dimension mode

- 99.999 to 99.999

9.000

#WVQ2

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

*.F

GO

HOLD

CALC

CHECK

LASER

BANK

0

1

2

3

HI

GO

LO

R.V. ANALOG

HI SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

V).X

HOLD CALC CHECK

F'(.V

LASER

BANK

0

1

2

3

HI

GO

LO

R.V. ANALOG

HI SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

V)*;U

HOLD CALC CHECK

Q((

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

&.;

GO

HOLD

CALC

CHECK

5. Hold function

Trigger level
setting screen

Hysteresis for
trigger level

[MODE]
or 

[MODE]
or 

[MODE]
or 

7. Delay timer