IB-E
NOTICE
Warming Up
Wait at least 30 minutes after turning the power on before starting
use. The circuit will be unstable immediately after the power is
turned on so the display value may gradually fluctuate.
Power On Reset
Once the power is turned on, it will take approx. 2 seconds for the
measurement to start. The judgment output will be output after the
response time (average number of times x sampling rate) has elapsed.
Other Precautions
WARNING
Power Supply
• The product could malfunction due to noise superimposed on the
power supply. Use a DC stabilized power supply with insulated
transformer for the power supply.
• When using a commercially-available switching regulator, always
ground the frame ground terminal.
Precautions on Regulations and Standards
NOTICE
CE Marking
Keyence corporation has confirmed that this product complies with
the essential requirements of the applicable EC Directives, based on
the following specifications. Be sure to consider the following
specifications when using this product in the Member States of
European Union.
EMC Directive
• Applicable standards
EMI: EN60947-5-2, Class A
EMS: EN60947-5-2
These specifications do not guarantee that the end-product with this
product incorporated complies with the essential requirements of
the EMC Directives. The manufacturer of the end-product is solely
responsible for ensuring the compliance of the end-product.
Low-voltage Directive
• Applicable standard: EN60825-1
UL Certification
This product is an UL/cUL Listed product.
• UL File No.
E301717
• Category: NRKH,
NRKH7
Be sure to consider the following specifications when using this
product as a UL/cUL Listed Product.
• Use the power supply with Class 2 output defined in NFPA70 (NEC:
National Electrical Code).
• The UL certificate for the IB series is for the sensor head and
amplifier used in combination. The IB series sensor head must be
used together with the IB series sensor amplifier unit exclusively.
• Power supply/ Control input/ Control output shall be connected to a
single Class 2 source only.
• Use with the over current protection device which is rated 30V or more
and not more than 1A.
• Use this product under pollution degree 2.