4-2 Basic Settings and Advanced Settings

4-8

4

Set
ting V

a

rious

F

unct

ions

IB-E

Select whether to display the received light (or blocked light) of the laser beam emitted to
the receiver as a dimension (mm) or a percentage (%) in respect to the measurement
range.

* The beam axis width applied during the dimension mode is as follows.

IB-01: 1 mm
IB-05: 5 mm
IB-10: 10 mm
IB-30: 30 mm
Example: If the received light currently used by the IB-10 is 50% (multiplier: 0.5), the

width will be displayed as 10 mm x 0.5 = 5 mm in the dimension mode.

The details displayed for each head model are as follow.

The above values are displayed when the received light mode is selected for the “2.
Received/Blocked light mode".

1. Measurement Mode

Measurement mode

Description

Default

value

% mode

Displays what percentage the current received light or
blocked light is in respect to the reference received light.

Dimension mode

Calculates what percent the current received light or
blocked light, multiples the result with the beam axis
width, and displays the final result as a dimension.

Dimension mode

% mode

IB-01

IB-05

IB-10

IB-30

Total received light

1.000

5.000

10.000

30.00

100.00

Semi-blocked

0.500

2.500

5.000

15.00

50.00

Total blockage

0.000

0.000

0.000

0.00

0.00