Measurement mode, Measurement mode -8 – KEYENCE IB Series User Manual
Page 60
4-2 Basic Settings and Advanced Settings
4-8
4
Set
ting V
a
rious
F
unct
ions
IB-E
Select whether to display the received light (or blocked light) of the laser beam emitted to
the receiver as a dimension (mm) or a percentage (%) in respect to the measurement
range.
* The beam axis width applied during the dimension mode is as follows.
IB-01: 1 mm
IB-05: 5 mm
IB-10: 10 mm
IB-30: 30 mm
Example: If the received light currently used by the IB-10 is 50% (multiplier: 0.5), the
width will be displayed as 10 mm x 0.5 = 5 mm in the dimension mode.
The details displayed for each head model are as follow.
The above values are displayed when the received light mode is selected for the “2.
Received/Blocked light mode".
1. Measurement Mode
Measurement mode
Description
Default
value
% mode
Displays what percentage the current received light or
blocked light is in respect to the reference received light.
Dimension mode
Calculates what percent the current received light or
blocked light, multiples the result with the beam axis
width, and displays the final result as a dimension.
Dimension mode
% mode
IB-01
IB-05
IB-10
IB-30
Total received light
1.000
5.000
10.000
30.00
100.00
Semi-blocked
0.500
2.500
5.000
15.00
50.00
Total blockage
0.000
0.000
0.000
0.00
0.00